Category:Emergency cart trolley
Time:2019/6/1 11:21:05

Product material composition:
Aluminum alloy column, drawer frame ABS, side plate, drawer panel, table pull plate for ABS material, guardrail for stainless steel tube, table panel for ABS.
Features: ABS panel, 2 trash bins, 5 drawers (1 large drawer, 2 middle drawers and 2 small drawers);
1 transparent folder, 1 movable drawing board (meal pulling board); ABS defibrillator platform; 1 salt water rack;
Additional rescue board, nylon oxygen bottle bracket and electrical equipment, broken needle bucket.
Ii. Size description :850*520*950MM
Iii. Structural details of each part
(1) defibrillation instrument platform --
Place medical equipment such as laptop computer, electrocardiogram tester, etc.
It can rotate 360 degrees. The computer tray is no more than 5KG.
(2) guardrail -- prevent items placed on the roof from falling out due to movement or other reasons.
(3) roof -- place medicines, salt bottles and other items (no more than 30KG).
(4) auxiliary work table -- a place for temporary storage (weight not exceeding 2KG).
(5) external shelf of document box -- for temporary storage of articles, such as medical records and documents
(6) file box switch -- press the switch to open the file box outwardly.
(7) file box -- place CT, files and other materials.
Note: the contents of the file box should not exceed 1KG
(8) casters -- with brake function
(9) salt water bottle hook -- hanging salt water bag (bottle), can be raised and lowered freely,
Note: single hook weight: 1KG.
(10) hand screw -- lifting switch of brine rack, and the brine rack locks.
(11) broken needle bucket -- temporary collection of needles, syringes and other medical waste.
(12) drawer lock -- lock the drawer.
(13) small drawer -- place corresponding items as required (set limit diameter of partition)
No more than 15KG per drawer.
(14) middle drawer -- place corresponding items as required (set limit diameter of partition)
No more than 15KG per drawer.
(15) large drawer -- place corresponding items as required (set limit diameter of partition)
No more than 15KG per drawer.
(16) defibrillation platform -- place medical equipment such as laptop computer, ecg tester, etc.
It can rotate 360 degrees. The computer tray is no more than 5KG.
(17) hand screw -- fix computer tray
(18) power socket -- to power electrical appliances on the computer tray
(socket voltage, style according to customer requirements).
(19) power switch -- power supply switch
(20) electrocardiogram recovery board switch --
Fix electrocardiogram recovery board to prevent falling out during movement.
(21) first aid board -- used in first aid.
(22) oxygen cylinder fixing band -- fix oxygen cylinder to prevent danger caused by pulling during movement.
(23) oxygen support -- used to place oxygen cylinders,
Note: the weight of the oxygen cylinder used should not exceed 13KG.
Cymbal wire machine - do not use power extension cord collection power cord use.
(25) power cord -- an extension cord to supply power to the socket.
(26) garbage canister -- temporary collection of garbage other than medical waste (individual weight not exceeding 3kg).
Cautions for safe use of products
1. Please do not stand on the roof or use the emergency vehicle as a platform, which may cause the vehicle body to overturn and cause injuries.
2. Please do not heat on the roof and other parts, and avoid direct contact with boiling water above 60°.
3. The ambulance is equipped with 4 casters, all of which have brake function. If you can't push, please check whether the casters are in the braking state.
4, meal pull board is used for temporary placement of goods, please do not place heavy objects, so as not to crush.
5. When pushing, please be careful not to let the caster crush over the power cord. Unplug the power cord if it is not used for a long time.
5. Please avoid storage in high temperature, damp and dusty environment. The temperature is -10℃ ~ 40℃, the relative humidity is not more than 80%RH, the atmospheric pressure range: 760hPa ~ 1060hPa. A well-ventilated room without corrosive gases.
Techniques for installation and use of products
After opening the package, please confirm whether all the following parts have been prepared. If any parts are insufficient or damaged, please contact the dealer or our company for after-sales service.
Number of unpacking parts
One main body of et-850 ambulance
1 needle processor
Computer tray 1
1 infusion rack
2 trash cans
1. Install the tray fixator of the computer tray at the upper left corner of the roof plate of the first aid truck, and use the hand screw switch to tighten and fix it.
2. Installation of broken needle cylinder place the broken needle cylinder directly in the hole on the right side of the roof plate of the emergency truck.
3. Installation of garbage can: hang the garbage can directly on the fixed hook on the right side panel of the emergency vehicle.
4. Product medicine box the medicine box is configured according to requirements, which can be pulled out at will.
6. Product cleaning and maintenance
When scrubbing, please soak the soft cloth with water diluted neutral detergent, wring dry scrub, and then wring the cloth soaked with water, wipe off the residual detergent components. Finally, dry it with a dry cloth. ※ do not use volatile substances (diluents, volatilizers, gasoline). Please do not rinse directly with water for fear of electric shock. ※ such products are not heat-resistant. Under the condition that thorough cleaning is required, please choose low-temperature disinfection method for sterilization.